SIRE 2.0 – WK : 58 – PRE-SIRE INSPECTION INSIGHTS

Vessel Preparation Review for Shell Vetting Inspection

Reference: For Shell Vetting Inspection

Inspector: Capt. Philip


Why Pre-SIRE Inspections Matter

During a sailing onboard, several latent weak barriers and operational gaps were identified across crew knowledge, procedural understanding, record management, and emergency preparedness.

Rather than waiting for an inspector to identify these shortcomings, focused onboard training, mentoring sessions, practical demonstrations, and evidence verification were conducted to strengthen the vessel’s readiness.

Outcomes Achieved

✅ Latent barriers identified

✅ Targeted onboard training delivered

✅ Gaps effectively addressed

✅ Crew confidence improved

✅ Evidence and records verified

✅ SIRE inspection successfully passed


BRIDGE – Non-Compliance Areas

ECDIS Navigation

  • Dual ECDIS failure procedures
  • Backup navigation arrangements
  • ENC update status
  • USB port control
  • Safety setting verification
  • Navigation Lights Panel checks and procedures

Compass & Navigation Equipment

  • Gyro repeater not matching Master Gyro
  • Magnetic compass spare bulb availability
  • Annual compass deviation table missing
  • Compass error records
  • NAVTEX corrections

Bridge Team Management

  • Manning requirements during watchkeeping
  • Watch handover procedures
  • Bell Book verification
  • Deck Log verification
  • Security and routing charts missing
  • BCAV assessments not completed

Radar & Collision Avoidance

  • Magnetron running hours not reset
  • Performance monitoring knowledge gaps
  • Collision avoidance settings awareness

BNWAS

  • Alarm sequence knowledge
  • Maintenance records
  • Activation and deactivation criteria
  • Overreliance on generic SMS procedures

Nautical Publications

  • Publication update procedures
  • Latest IAMSAR Volume III missing onboard

Passage Planning

  • Air draft calculation errors
  • Wheel Over Point (WOP) procedures
  • High-risk area procedures
  • Route check procedures

GMDSS

  • Weekly and monthly testing compliance
  • Communication officer designation records
  • Emergency lighting defects at GMDSS station

CCR – Non-Compliance Areas

Cargo Planning

  • Cargo planning not fully satisfactory
  • Critical cargo stages not adequately addressed
  • COW plan verification gaps
  • Planned versus actual cargo stage comparison

Loadicator

  • Latest test condition comparison not verified

ODME

  • Operational testing deficiencies
  • Oil Record Book verification issues

Inert Gas System

  • Secondary pressure settings
  • IG log review
  • Lack of familiarity with HI/HIHI setting procedures

Ship/Shore Safety Checklist (SSSCL)

  • ISGOTT 6 checklist non-compliance
  • Limited crew familiarity with checklist requirements

Emergency Response

  • IG failure response knowledge gaps
  • Junior officer decision-making capability in absence of senior officers

Gas Detection Equipment

  • Span gas calibration demonstration
  • CO₂ span gas unavailable as per new requirements

DECK – Key Non-Compliance Areas

  • Expired rocket parachute flares in lifeboat
  • Immersion suit pressure testing verification
  • Crew unfamiliarity with updated ERP Manual
  • Crew unfamiliarity with CO₂ meter requirements
  • Errors identified in enclosed space entry checklist
  • Multiple manifold non-compliances
  • Deck machinery operating procedures knowledge gaps
  • Water accumulation in inert gas line due to prolonged non-draining

ENGINE ROOM – Top Non-Compliance Areas

  • Work & Rest Hours non-compliance
  • Risk assessment familiarity issues
  • PMS running hour mismatches
  • ISM manual familiarity
  • Defect reporting procedures
  • Class notification process
  • Lube oil analysis records
  • Fuel oil analysis records
  • Welding and hot work procedures
  • Pollution prevention equipment
  • BDN documentation
  • Emergency diesel generator operation
  • OWS records
  • Bilge alarm records
  • Dead Man Alarm records
  • UMS records not aligned with Work & Rest Hours and bridge logbook entries
  • Fire alarm test records

PRE-SIRE RED FLAGS IDENTIFIED

⚠ Weak PMS familiarity among crew

⚠ Limited understanding of defect reporting processes

⚠ Analysis reports not readily retrievable

⚠ Inadequate awareness of hot work procedures

⚠ Welding equipment compliance concerns

⚠ Poor familiarity with OWS and incinerator capacities

⚠ BDN filing and retrieval weaknesses

⚠ Emergency generator operational knowledge gaps

⚠ Incomplete safety testing records

⚠ Work & Rest Hours and Risk Assessment deficiencies


PRE-SIRE FOCUS SCORECARD

Bridge ⭐⭐⭐⭐

Ccr ⭐⭐⭐

Deck ⭐⭐⭐⭐

Engine room ⭐⭐⭐

SMS ⭐⭐⭐

Procedure awareness ⭐⭐

Record keeping ⭐⭐⭐

Housekeeping ⭐⭐⭐⭐⭐


SELF-ASSESSMENT QUESTION

Can your team locate the required procedure, record, and supporting evidence within 60 seconds when questioned by an inspector?

Find the gap. Strengthen the barrier. Build crew confidence. Success will follow.